Fire
Fire classification is a property of a grade at a tested thickness, not of a product name. Every result below states the product, the grade, the standard and — where the report gives one — the thickness the panel was tested at.
01
TOPAZ
EN 13501-1:2018 · EN 13823:2020+A1:2022 · EN ISO 11925-2
Classification
B-s1, d0
| Property | Requirement | Result |
|---|---|---|
| FIGRA₀.₂MJ | ≤ 120 W/s | 26.1 W/s |
| FIGRA₀.₄MJ | ≤ 120 W/s | 18.3 W/s |
| Lateral flame spread | No LFS to edge | None |
| Total heat release, THR₆₀₀s | ≤ 7.5 MJ | 2.4 MJ |
| SMOGRA | ≤ 30 m²/s² | 1.5 m²/s² |
| Total smoke production, TSP₆₀₀s | ≤ 50 m² | 27.7 m² |
| Flaming droplets / particles | None ≥ 10 s within first 600 s | None |
| Ignitability | Flame must not reach 150 mm mark | Not reached |
VIR TOPAZ (CGS / CGF) — Product Data Sheet · p. 4 · Full test report supplied on request
02
VAULT
EN 13501-1:2018 · EN 13823:2020+A1:2022 · EN ISO 11925-2
Classification
B-s1, d0
| Property | Requirement | Result |
|---|---|---|
| FIGRA₀.₂MJ | ≤ 120 W/s | 26.1 W/s |
| FIGRA₀.₄MJ | ≤ 120 W/s | 18.3 W/s |
| Lateral flame spread | No LFS to edge | None |
| Total heat release, THR₆₀₀s | ≤ 7.5 MJ | 2.4 MJ |
| SMOGRA | ≤ 30 m²/s² | 1.5 m²/s² |
| Total smoke production, TSP₆₀₀s | ≤ 50 m² | 27.7 m² |
| Flaming droplets / particles | None ≥ 10 s within first 600 s | None |
| Ignitability | Flame must not reach 150 mm mark | Not reached |
VIR VAULT (CGS / CGF) — Product Data Sheet · p. 2 · Full test report supplied on request
03
KLADS
EN 13501-1:2018 · EN 13823:2020+A1:2022 · EN ISO 11925-2
Classification
B-s1, d0
| Property | Requirement | Result |
|---|---|---|
| FIGRA₀.₂MJ | ≤ 120 W/s | 16.15 W/s |
| Lateral flame spread | No LFS to edge | None |
| Total heat release, THR₆₀₀s | ≤ 7.5 MJ | 4.42 MJ |
| SMOGRA | ≤ 30 m²/s² | 0 m²/s² |
| Total smoke production, TSP₆₀₀s | ≤ 50 m² | 29.11 m² |
| Flaming droplets / particles | None ≥ 10 s within first 600 s | None |
| Ignitability | Flame must not reach 150 mm mark | Not reached |
VIR KLADS (EDS / EDF) — Product Data Sheet · p. 2 · Full test report supplied on request
ASTM E84-23
Classification
Class A / Class I
| Property | Requirement | Result |
|---|---|---|
| Flame spread index | 0–25 | 20 |
| Smoke developed index | 0–450 | 80 |
VIR KLADS (EDS / EDF) — Product Data Sheet · p. 2 · Full test report supplied on request
BS 476 Part 7:1997
Classification
Class 1
| Property | Requirement | Result |
|---|---|---|
| Flame spread at 1½ minutes | ≤ 165 mm | 0 mm |
| Final flame spread | ≤ 165 mm | 0 mm |
VIR KLADS (EDS / EDF) — Product Data Sheet · p. 2 · Full test report supplied on request
BS 476 Part 6:1989+A1:2009
Classification
Reported
| Property | Requirement | Result |
|---|---|---|
| Fire propagation index | Tested value | 11.6 |
| Sub-index i₁ | Reported | 2.3 |
| Sub-index i₂ | Reported | 3.5 |
| Sub-index i₃ | Reported | 5.8 |
VIR KLADS (EDS / EDF) — Product Data Sheet · p. 2 · Full test report supplied on request
UL 94:1997 (20 mm)
Classification
V-0
| Property | Requirement | Result |
|---|---|---|
| After-flame time t₁ | < 10 s | 0 s |
| After-flame time t₂ | < 10 s | 0 s |
| Total after-flame time | < 50 s | 0 s |
| After-glow time t₃ | < 30 s | 0 s |
VIR KLADS (EDS / EDF) — Product Data Sheet · p. 2 · Full test report supplied on request
Two values in the source documentsC08
ASTM E84 result
- FSI 20 / SDI 80 — KLADS EDF, 6 mm — stated in VIR KLADS (EDS / EDF) — Product Data Sheet, p. 2
- FSI 25 / SDI 150 — HPL, generic — stated in Fire Performance, p. 2
The manufacturer's documents state more than one value for this. Both are shown with the document each came from. Nothing is published as fact until Rushil Decor confirms which applies.
Request confirmationReaction-to-fire classification applies to the panel as tested. It does not certify a complete façade construction, which is assessed as a system including substructure, cavity and fixings.