RUSHIL DECOR

Fire

Fire classification is a property of a grade at a tested thickness, not of a product name. Every result below states the product, the grade, the standard and — where the report gives one — the thickness the panel was tested at.

01

TOPAZ

Applies to grade CGF onlyOn request

EN 13501-1:2018 · EN 13823:2020+A1:2022 · EN ISO 11925-2

Classification

B-s1, d0

PropertyRequirementResult
FIGRA₀.₂MJ≤ 120 W/s26.1 W/s
FIGRA₀.₄MJ≤ 120 W/s18.3 W/s
Lateral flame spreadNo LFS to edgeNone
Total heat release, THR₆₀₀s≤ 7.5 MJ2.4 MJ
SMOGRA≤ 30 m²/s²1.5 m²/s²
Total smoke production, TSP₆₀₀s≤ 50 m²27.7 m²
Flaming droplets / particlesNone ≥ 10 s within first 600 sNone
IgnitabilityFlame must not reach 150 mm markNot reached

VIR TOPAZ (CGS / CGF) — Product Data Sheet · p. 4 · Full test report supplied on request

02

VAULT

Applies to grade CGF onlyOn request

EN 13501-1:2018 · EN 13823:2020+A1:2022 · EN ISO 11925-2

Classification

B-s1, d0

PropertyRequirementResult
FIGRA₀.₂MJ≤ 120 W/s26.1 W/s
FIGRA₀.₄MJ≤ 120 W/s18.3 W/s
Lateral flame spreadNo LFS to edgeNone
Total heat release, THR₆₀₀s≤ 7.5 MJ2.4 MJ
SMOGRA≤ 30 m²/s²1.5 m²/s²
Total smoke production, TSP₆₀₀s≤ 50 m²27.7 m²
Flaming droplets / particlesNone ≥ 10 s within first 600 sNone
IgnitabilityFlame must not reach 150 mm markNot reached

VIR VAULT (CGS / CGF) — Product Data Sheet · p. 2 · Full test report supplied on request

03

KLADS

Applies to grade EDF onlyTested on 6 mmOn request

EN 13501-1:2018 · EN 13823:2020+A1:2022 · EN ISO 11925-2

Classification

B-s1, d0

PropertyRequirementResult
FIGRA₀.₂MJ≤ 120 W/s16.15 W/s
Lateral flame spreadNo LFS to edgeNone
Total heat release, THR₆₀₀s≤ 7.5 MJ4.42 MJ
SMOGRA≤ 30 m²/s²0 m²/s²
Total smoke production, TSP₆₀₀s≤ 50 m²29.11 m²
Flaming droplets / particlesNone ≥ 10 s within first 600 sNone
IgnitabilityFlame must not reach 150 mm markNot reached

VIR KLADS (EDS / EDF) — Product Data Sheet · p. 2 · Full test report supplied on request

Applies to grade EDF onlyTested on 6 mmOn request

ASTM E84-23

Classification

Class A / Class I

PropertyRequirementResult
Flame spread index0–2520
Smoke developed index0–45080

VIR KLADS (EDS / EDF) — Product Data Sheet · p. 2 · Full test report supplied on request

Applies to grade EDF onlyTested on 6 mmOn request

BS 476 Part 7:1997

Classification

Class 1

PropertyRequirementResult
Flame spread at 1½ minutes≤ 165 mm0 mm
Final flame spread≤ 165 mm0 mm

VIR KLADS (EDS / EDF) — Product Data Sheet · p. 2 · Full test report supplied on request

Applies to grade EDF onlyTested on 6 mmOn request

BS 476 Part 6:1989+A1:2009

Classification

Reported

PropertyRequirementResult
Fire propagation indexTested value11.6
Sub-index i₁Reported2.3
Sub-index i₂Reported3.5
Sub-index i₃Reported5.8

VIR KLADS (EDS / EDF) — Product Data Sheet · p. 2 · Full test report supplied on request

Applies to grade EDF onlyTested on 6 mmOn request

UL 94:1997 (20 mm)

Classification

V-0

PropertyRequirementResult
After-flame time t₁< 10 s0 s
After-flame time t₂< 10 s0 s
Total after-flame time< 50 s0 s
After-glow time t₃< 30 s0 s

VIR KLADS (EDS / EDF) — Product Data Sheet · p. 2 · Full test report supplied on request

Two values in the source documentsC08

ASTM E84 result

  • FSI 20 / SDI 80 — KLADS EDF, 6 mm — stated in VIR KLADS (EDS / EDF) — Product Data Sheet, p. 2
  • FSI 25 / SDI 150 — HPL, generic — stated in Fire Performance, p. 2

The manufacturer's documents state more than one value for this. Both are shown with the document each came from. Nothing is published as fact until Rushil Decor confirms which applies.

Request confirmation

Reaction-to-fire classification applies to the panel as tested. It does not certify a complete façade construction, which is assessed as a system including substructure, cavity and fixings.

Technical data is based on manufacturer documentation and applicable test reports. Product specifications may vary by grade, thickness, décor, manufacturing batch or application. Please request the latest technical documentation before final specification or installation.